From 7c4908184b11542125f586c7ed2218bdf33f4f4b Mon Sep 17 00:00:00 2001 From: Petr Krasnoshchekov Date: Mon, 9 Oct 2023 12:43:20 +0500 Subject: base-sim: increase operator identifier loading timeout SIMCOM A760xE-H modems can answer to AT+CRSM=176,28589,0,0,4 request in 10s or more, so use rather big timeout (20s) --- src/mm-base-sim.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-) diff --git a/src/mm-base-sim.c b/src/mm-base-sim.c index 63b1173f..d70bf563 100644 --- a/src/mm-base-sim.c +++ b/src/mm-base-sim.c @@ -2147,11 +2147,13 @@ load_operator_identifier (MMBaseSim *self, { mm_obj_dbg (self, "loading operator ID..."); - /* READ BINARY of EFad (Administrative Data) ETSI 51.011 section 10.3.18 */ + /* READ BINARY of EFad (Administrative Data) ETSI 51.011 section 10.3.18 + * SIMCOM A760xE-H modems can answer in 10s or more, so use rather big timeout + */ mm_base_modem_at_command ( self->priv->modem, "+CRSM=176,28589,0,0,4", - 10, + 20, FALSE, (GAsyncReadyCallback)load_operator_identifier_command_ready, g_task_new (self, NULL, callback, user_data)); -- cgit v1.2.3-70-g09d2