aboutsummaryrefslogtreecommitdiff
path: root/docs/reference/api/ModemManager-migration-reference.xml
diff options
context:
space:
mode:
authorJessy Diamond Exum <jessy.exum@meraki.net>2020-08-26 13:52:04 -0700
committerAleksander Morgado <aleksander@aleksander.es>2020-09-15 07:35:04 +0000
commitb1679b58939fc2563b827d478ac0eea937fd16c8 (patch)
treeb093254b1af349c4a0f94a4475b7a37814e9724c /docs/reference/api/ModemManager-migration-reference.xml
parentaf5c242e9234a7061ec0d6624e3712153c7c2c6b (diff)
cinterion: Configure the PLAS9 to correctly send Unsolicited Result Codes.
The PLS8 and PLAS9 modems (and likely many others modems supported by this driver) have two AT capable serial ports: The 'MODEM' AT port (default for PPP) and the 'APPLICATION' AT port (used for general control). The PLS8 modem sends URCs to the APPLICATION port by default, while he PLAS9 defaults sending URCs to the MODEM port. To get URCs to behave on both modems, it is necessary to explicitly set the URC reporting port to APPLICATION.
Diffstat (limited to 'docs/reference/api/ModemManager-migration-reference.xml')
0 files changed, 0 insertions, 0 deletions